On the ADVIA Centaur XP system are the same as those on the ADVIA Centaur XPT system— we did not see it as a priority to perform method comparison evaluations between the two systems. Objectives of the ADVIA Centaur XPT Immunoassay System Assessment. Compare manual hands-on time for maintenance tasks and identify time savings. The Centaur software manuals are automatically installed on your computer. To locate a software manual, click Start JPrograms JCDV Americas JCentaur JAdministration Console JManuals. The Centaur hardware manuals must be manually installed on your computer. To locate the hardware manuals on the CD, open Windows Explorer.
One moment please...
- Parts
- Videos
- News
DESCRIPTION
Two-dimensional Platelet analysis using a combination of Laser Light Scatter and cytochemical staining, providing higher confidence.The ADVIA 2120 and ADVIA 2120i Hematology Systems are fully automated analyzers that perform Complete Blood Counts with Differential, Reticulocyte analysis and Two-dimensional Platelet analysis using a combination of Laser Light Scatter and cytochemical staining, providing higher confidence and better efficiency. CSF analysis reduces manual operator intervention and improves turn around time.
In addition, Flexible sampling modes and onboard reagents allow you to maximize your precious resources: blood, operator safety, workspace, and storage areas. The ADVIA® 2120 Hematology System gets the job done and gets it right the first time, with a review rate far lower than competing systems.
In addition, Flexible sampling modes and onboard reagents allow you to maximize your precious resources: blood, operator safety, workspace, and storage areas. The ADVIA® 2120 Hematology System gets the job done and gets it right the first time, with a review rate far lower than competing systems.
FORUMSView All (7)
Ask a New Question0Repliesa year ago | a year agoRBC data I've been told that we are to report out the RBC interpretations (Hypo, hyper, aniso, etc) from the Advia 2120 instead of what is seen when doing slide reviews and manual differentials. Has the analyzer been approved for this? Is it truly better than the human eye in reporting?Reply |
-Engineer Khaleeque 3 years ago | 3 years agoNEED pm CHECK LIST I NEED PM CHECK LIST FOR ADVIA 212I Reply |
0Replies3 years ago | 3 years agocommunication structure of message advia 2120 principe d'echange et de communication port serie Reply |
DOCUMENTS / MANUALSView All
FEATURES
- ADVIA 2120 and ADVIA 2120i technology utilize Peroxidase stain, the gold standard for WBC differentials, therefore, delivering better agreement with your technologists’ manual results- providing higher confidence, better efficiency.
- True RBC morphology advances cell separation to a new level that allows for the differentiation of various disease states, including those associated with anemia.
- Maximize the effectiveness of costly platelet transfusions with accurate results the first time, every time - even at very low platelet levels. Two dimensional optical platelets analyze both extra-cellular and intracellular properties, ensuring that large platelets are included in your counts, and known interferences are not.
- Rack-based capacity for 150 samples delivers all the benefits of 'walkaway' convenience.
- Fixed throughput of CBC/Diff at 120 samples per hour, even on leukopenic samples, provides fast results reporting to enhance the service to clinicians.
- Proven technology, reference methods and onboard delta checks reduce manual slide reviews.
- Increased linearities minimize costly, timeconsuming dilutions and repeat.
- Differentiates microcytic anemias with advanced RBC and reticulocyte technology
- Automates hematology workflow without the need for large track-based systems, expensive stains, or reflexive testing
- Delivers gold standard flow cytometry peroxidase methodology for optimum results
- Simplifies maintenance through reduced fluidics, eliminated pinch valves, and automated daily cleaning using Unifluidics™ Technology
SPECIFICATIONS
Height | 33.8 in Analytical Module with Autosampler |
Length | 26.8 in Analytical Module with Autosampler |
Weight | 425 lbs Analytical Module with Autosampler |
Width | 55.5 in Analytical Module with Autosampler |
Additional Specifications
Advia Centaur Xp Reference Manual Pdf
Performance Specifications
WBC 0.02 to 400 x 103/µL
RBC 0.0 to 7.0 x 106/µL
PLT 5.0 to 3500 x 103/µL
HB 0.0 to 22.5 g/dL
Retic 0.2 to 24.5%
Test Selectivity / Throughput
CBC 120 Samples/hr.
CBC/DIFF 120 Samples/hr.
CBC/DIFF/Retic 74 Samples/hr.
CBC/Retic 74 Samples/hr.
Retic 74 Samples/hr.
Sample Modes / Volumes
Automatic
Closed Tube 175µL.
Manual
Closed Tube 175µL.
Manual
Auto Sampler Option
150 Sample Capacity: 15 Racks with 10 tube capacity
Compatible Tube Types: VACUTAINER®, HEMOGARD®, Monovette®, Venoject®II, Venosafe®, Vacuette®, Monoject®
Bar Code Reader: Up to 14 digits
Automatic discrimination of label codes: Codabar
Interleave 2 of 5 with and without check digit
Code 39
Code128 EAN and JAN (8 and 13)
Open Tube 175µL.
WBC 0.02 to 400 x 103/µL
RBC 0.0 to 7.0 x 106/µL
PLT 5.0 to 3500 x 103/µL
HB 0.0 to 22.5 g/dL
Retic 0.2 to 24.5%
Test Selectivity / Throughput
CBC 120 Samples/hr.
CBC/DIFF 120 Samples/hr.
CBC/DIFF/Retic 74 Samples/hr.
CBC/Retic 74 Samples/hr.
Retic 74 Samples/hr.
Sample Modes / Volumes
Automatic
Closed Tube 175µL.
Manual
Closed Tube 175µL.
Manual
Auto Sampler Option
150 Sample Capacity: 15 Racks with 10 tube capacity
Compatible Tube Types: VACUTAINER®, HEMOGARD®, Monovette®, Venoject®II, Venosafe®, Vacuette®, Monoject®
Bar Code Reader: Up to 14 digits
Automatic discrimination of label codes: Codabar
Interleave 2 of 5 with and without check digit
Code 39
Code128 EAN and JAN (8 and 13)
Open Tube 175µL.